Constraining Exclusive Clock Groups - 2023.2 English

Versal Adaptive SoC Hardware, IP, and Platform Development Methodology Guide (UG1387)

Document ID
UG1387
Release Date
2023-11-15
Version
2023.2 English

You can use the regular timing or clock network reports to review the clock paths and identify the situations where two clocks propagate on a same clock tree and are used at the same time in a timing path where the startpoint and endpoint clock pins are connected to the same clock tree. This analysis can be a time consuming task. Instead, you can review the multiple_clock section of the Check Timing report. This section returns a list of clock pins and their associated timing clocks.

Based on the clock tree topology, you must apply different constraints as described in the following sections.