Active and Passive Card Configurations

VCK5000 Data Center Acceleration Development Kit Hardware Installation Guide (UG1531)

Document ID
UG1531
Release Date
2023-07-19
Revision
1.1 English

The AMD VCK5000 Versal development card can be configured as an actively or passively cooled card depending on the addition of the fan assembly.

An AMD VCK5000 Versal development card configured with a fan assembly attached is referred to as the active configuration. The fan assembly provides air flow to cool the card. The card comes preconfigured with a fan assembly and PCIe AUX cables attached. In the active configuration the AUX power cables are exiting from the back side of the card and require additional spacing, exceeding the form factor (shown in the following figure).
Figure 1. Active Configuration
When the fan assembly is removed, it is referred to as the passive configuration. The passive cooling configuration requires external air flow to provide direct cooling to the card. Operation of a passively configured card without external cooling will cause damage to the card.
Figure 2. Passive Configuration

Steps to install and remove the card fan assembly are provided in Fan Assembly Removal and Installation.

CAUTION:
If the fan assembly is removed from the card and the card is powered-up, external fan cooling airflow MUST be applied to prevent over-temperature shut-down and possible damage to the card electronics.