Transmitter Termination

UltraScale Architecture SelectIO Resources User Guide (UG571)

Document ID
UG571
Release Date
2023-08-31
Revision
1.15 English

The LVDS transmitter does not require any external termination. Table: Allowed Attributes for the LVDS I/O Standards lists the allowed attributes corresponding to the LVDS current-mode drivers. LVDS current-mode drivers are a true current source and produce the proper (EIA/TIA compliant) LVDS signal.