close_bd_design - 2023.2 English

Vivado Design Suite Tcl Command Reference Guide (UG835)

Document ID
UG835
Release Date
2023-10-18
Version
2023.2 English

Close a design.

Syntax

close_bd_design [‑quiet] [‑verbose] <name>

Returns

The design object, "" if failed.

Usage

Name Description
[-quiet] Ignore command errors
[-verbose] Suspend message limits during command execution
<name> Name of design to close

Categories

IPIntegrator

Description

Closes the specified IP subsystem design in the IP integrator of the AMD Vivado™ Design Suite.

If the design has been modified, you will not be prompted to save the design prior to closing. You will need to run save_bd_design to save any changes made to the design before using the close_bd_design command.

Arguments

-quiet - (Optional) Execute the command quietly, returning no messages from the command. The command also returns TCL_OK regardless of any errors encountered during execution.
Note: Any errors encountered on the command-line, while launching the command, will be returned. Only errors occurring inside the command will be trapped.
-verbose - (Optional) Temporarily override any message limits and return all messages from this command.
Note: Message limits can be defined with the set_msg_config command.

<name> - The name of the IP subsystem design object to close.

Example

The following example closes the current IP subsystem design in the current project:

close_bd_design [current_bd_design]