CAN FD

Versal Adaptive SoC PCB Design User Guide (UG863)

Document ID
UG863
Release Date
2023-09-14
Revision
1.7 English
  • A level shifter must be implemented if using a CAN PHY that operates at a voltage higher than the Versal adaptive SoC.
  • Ensure VIH/VIL and VOH/VOL levels are met for both the Versal and CAN devices
    • Versal device values can be found in the PSIO Levels section of the Versal adaptive SoC data sheets.
    • Be sure to choose the correct levels for the voltage used (i.e., LVCMOS18, LVCMOS33).