Open the Implemented Design - 2023.2 English

Vivado Design Suite Tutorial: Design Flows Overview (UG888)

Document ID
UG888
Release Date
2023-10-19
Version
2023.2 English
  1. Select Open Implemented Design in the Flow Navigator.
  2. If prompted, select Yes to close the synthesized design and Don’t Save.

    A dialog might indicate that there are methodology violations in the design. Select OK to acknowledge the violations.

    You can see the Implemented Design displayed in the Device window.

    Note: Upon opening the implemented design, you might receive a warning indicating methodology violations exist in the design. If this were an actual design, you should run report_methodology to view and correct any violation. For this tutorial, you will ignore these violations.
  3. Click the Reports tab at the bottom of the Vivado IDE.

    If the Reports window is not open, you can open it with Windows > Reports. Select and examine some of the reports from Place Design and Route Design. Close each of the reports when you are done.

  4. Select the Messages tab at the bottom of the IDE.

    If the Messages window is not open, you can open it with Windows > Messages.

  5. Click the Collapse All button to condense all of the Messages.
  6. Expand the Implementation folder.
  7. View the messages from Design Initialization, Opt_Design, Place_Design, and Route_Design.