  • Specify a reset or power-up state for Vivado synthesis to identify a Finite State Machine (FSM) or set the value of FSM_ENCODING to "none".
  • The State Register can be asynchronously or synchronously reset to a particular state.
Note: Use synchronous reset logic over asynchronous reset logic for an FSM.