Sampling Point Shift

Clock and Data Recovery Unit based on Deserialized Oversampled Data (XAPP1240)

Document ID
XAPP1240
Release Date
2022-11-04
Revision
3.1 English

The eye-scan feature comes at a price in terms of resources (see Resources). To save hardware resources, it is possible to shift the NIDRU sampling point inside the eye to measure the eye aperture. With this method, the eye scan can be performed only during a debug session, because bit errors are visible as soon as the sampling phase is pushed closer to the borders of the eye.

The port SHIFT_S_PH can be used to move the sampling point. The port is specified in twos complement. By setting SHIFT_S_PH to 0 (default) the NIDRU samples the incoming data stream in the middle of the eye.

The eye scan ports operate independently on the port SHIFT_S_PH, in the sense that each eye scan is always performed relative to the middle of the eye diagram, and not to the setting of SHIFT_S_PH.