eFUSE Programming Conditions

Spartan-7 FPGAs Data Sheet: DC and AC Switching Characteristics (DS189)

Document ID
DS189
Release Date
2022-10-31
Revision
1.10 English

Table: eFUSE Programming Conditions(1) lists the programming conditions specifically for eFUSE. For more information, see the 7 Series FPGA Configuration User Guide (UG470) [Ref 10].

Table  52:   eFUSE Programming Conditions(1)

Symbol

Description

Min

Typ

Max

Units

IFS

VCCAUX supply current

115

mA

Tj

Temperature range

15

125

°C

Notes:

1.The FPGA must not be configured during eFUSE programming.