- In the Open IP Example Design Vivado project, under Flow Navigator, select
Simulation Settings.
- Select Vivado Simulator as the Target simulator.
- Under the Simulation tab, set the xsim.simulate.runtime to 1 ms
(there are simulation RTL directives which stop the simulation after a certain
period of time, which is less than 1 ms) as shown in the following figure. The
Generate simulation scripts only option generates simulation scripts only. To run
behavioral simulation, Generate Scripts Only option must be de-selected.
- Set the Simulation Language to Mixed.
- Apply the settings and select OK.
- In the Flow Navigator window, select Run
Simulation and Run Behavioral
Simulation as shown:
-
Vivado invokes Vivado simulator and
simulations are run in the Vivado simulator tool. For more
information, see the
Vivado Design Suite User Guide: Logic
Simulation (UG900).